Altronix | AL1024ULACMCB | UL 10A 8 OUT ACCESS SPLY W/CB

No reviews yet Write a Review
SKU:
AX-AL1024ULACMCB

Description

  • Input
    • Input 115VAC 60Hz rated @ 4.2A.
      • Power supply input options:
        • a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
        • b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
    • Eight (8) Access Control System trigger inputs.
      • Input options:
        • a) Eight (8) normally open (NO) inputs.
        • b) Eight (8) open collector inputs.
        • c) Any combination of the above.
  • Output
    • 24VDC @ 10A supply current.
    • Class 2 Rated PTC protected power limited auto-resettable outputs.
    • Eight (8) independently controlled outputs.
      • Output options:
        • Eight (8) Fail-Safe and/or Fail-Secure power outputs.
        • Eight (8) auxiliary power outputs (unswitched).
      • Output ratings:
        • PTCs are rated @ 2.5A.
    • Filtered and electronically regulated outputs (built-in power supply).
    • ACM8 board main fuse is rated at 10A.
  • Supervision
    • AC fail supervision (form "C" contacts).
    • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
    • Low battery and battery presence supervision (form "C" contact).
  • Features
    • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
      • Fire Alarm disconnect input options:
        • a) Normally open (NO) or normally closed (NC) dry contact input.
        • b) Polarity reversal input from FACP signaling circuit.
    • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
    • Short circuit and thermal overload protection.
  • Visual Indicators
    • Red LEDs indicate outputs are triggered (relays energized).
    • Green LED indicates FACP disconnect is triggered.
    • AC input and DC output LED indicators.
  • Battery Backup
    • Built-in charger for sealed lead acid or gel type batteries.
    • Automatic switch over to stand-by battery when AC fails.
    • Zero voltage drop when unit switches over to battery backup (AC failure condition).
    • AC fail supervision (form "C" contact).
    • Battery fail and battery presence supervision (form "C" contact).
  • Temperature
    • Operating 0ºC to 49ºC ( 32ºF to 120ºF ).
    • Storage - 20ºC to 70ºC ( -4ºF to 158ºF ).
    • Relative Humidity 85% +/- 5%.
    • BTU/Hr. (approx.): 123 BTU/Hr.

 