The V-SLC2-1 drops a second 250-point signaling line loop into a Kidde VS4 fire alarm control panel, taking the system from one addressable loop to two without a panel swap. It occupies one of the VS4's expansion slots and supports up to 125 detectors and 125 modules on the added loop.

Built for the commercial fire installer

On jobs where the base VS4 loop runs out of headroom mid-project, the V-SLC2-1 is the straightforward fix: field-install the card, wire the new loop, and the panel picks it up through its existing addressing scheme. No reprogramming the base loop, no new enclosure. It's also the right call on retrofit and expansion jobs where the customer's device count grew past what a single loop supports.

Key features

  • Adds a full 250-point loop: up to 125 detectors and 125 modules on the new circuit
  • Field-installs in an expansion slot: no separate enclosure or backbox required
  • VS4-specific: designed for the VS4 panel's dual-loop expansion architecture
  • Up to 20,000 ft. of wiring per loop supported on the added circuit

System compatibility

For Kidde VS4 Series intelligent fire alarm control panels only. Each VS4 panel accepts up to two loop controller modules in any combination of single (V-SLC2-1) or dual (V-SLC2-2) loops, on top of the one 250-point loop built into the base panel.

Brand:
Kidde Commercial
Form factor:
SLC loop expansion card, VS4 expansion slot mount
Compatible panels:
Kidde VS4 Series intelligent fire alarm control panels only
Loop capacity:
250 addressable devices: 125 detectors, 125 modules
Wiring distance:
Up to 20,000 ft. (6,096 m) per loop
Installation:
Occupies one of two VS4 expansion slots; no separate enclosure needed
What does the V-SLC2-1 do?
It adds a second 250-point signaling line loop to a Kidde VS4 fire alarm panel, supporting up to 125 detectors and 125 modules on the new circuit.
What panels is this compatible with?
Kidde VS4 Series intelligent fire alarm control panels only. It is not compatible with VS1 (single-loop) panels.
How does this differ from the V-SLC2-2?
The V-SLC2-1 adds one 250-point loop. The V-SLC2-2 adds two 250-point loops (500 devices total) in the same expansion slot.
Does installing this require reprogramming the existing loop?
No. The V-SLC2-1 installs in an available VS4 expansion slot and the panel addresses the new loop independently of the base loop's existing configuration.