Kidde | Integrity 110 cd Wall Mount Temporal Horn/Strobe, 24 VDC, White, UL1971 Listed | INT-8ATW

No reviews yet Write a Review
SKU:
KD-INT-8ATW

The Kidde Integrity INT-8ATW is a 110 cd temporal horn/strobe built for commercial fire alarm notification on 24 VDC NAC circuits. Wall-mount form factor in white housing, UL1971 listed at 110 cd in the "FIRE" wall orientation - rated for sleeping area notification without supplemental devices.

Built for the commercial installer

The Integrity series drops onto standard 4-inch square electrical boxes and ties into existing 24 VDC NAC loops. Temporal (Code 3) horn pattern meets NFPA 72 evacuation signaling requirements out of the box. UL1971 listing at 110 cd covers sleeping area applications where strobe output thresholds are tighter than general notification zones.

Key features

  • 110 cd strobe output - UL1971 listed in wall orientation, meets sleeping area notification thresholds
  • Temporal (Code 3) horn pattern - NFPA 72 compliant evacuation signal, no field programming needed
  • 24 VDC operation - connects directly to standard NAC circuits from any compatible FACP
  • Wall mount, white housing - clean installation on standard 4-inch electrical boxes
  • Combined horn/strobe - audible and visual notification from a single device, reducing device count per zone

System requirements

Requires a 24 VDC NAC circuit from a compatible fire alarm control panel (FACP). Mounts to a standard 4-inch square electrical box. Verify NAC circuit current capacity against total connected device load before adding to an existing loop.

Brand:
Kidde Commercial
Form factor:
Wall mount horn/strobe
Power input:
24 VDC (NAC circuit)
Strobe output:
110 cd
Strobe orientation:
Wall mount, "FIRE" marking
Horn pattern:
Temporal (Code 3)
Color:
White
Compliance:
UL1971, NFPA 72
Sleeping area rated:
Yes, at 110 cd wall orientation
Does this horn/strobe meet sleeping area requirements?
Yes. The INT-8ATW is UL1971 listed at 110 cd in the wall "FIRE" orientation, which meets the strobe intensity threshold for sleeping area notification per NFPA 72.
What NAC voltage does this device require?
24 VDC. It connects to a standard 24-volt NAC (Notification Appliance Circuit) from any compatible fire alarm control panel.
What horn pattern does this device produce?
Temporal Code 3 pattern - the standard NFPA 72 evacuation signal (three pulses, pause, repeat). No field programming required.
What mounting box does this require?
Standard 4-inch square electrical box. Wall mount orientation.
Can I mix this with Genesis notification appliances on the same NAC loop?
Yes, provided all devices on the loop are rated for the same NAC voltage (24 VDC) and the total current draw does not exceed the FACP's NAC circuit capacity. Verify sync module compatibility if synchronized strobe operation is required.

Spec Sheet