Kidde | Agent Releasing Module - Intelligent 2-Circuit | GSA-REL

No reviews yet Write a Review
SKU:
KD-GSA-REL

The GSA-REL is an intelligent addressable releasing module that controls sprinkler, pre-action, and deluge systems, and can release clean-agent or gaseous suppression such as CO2, Halon, or foam Ć¢ā‚¬ā€ all communicating directly over the fire alarm panel's Signature loop, with no separate releasing panel required.

Built for the commercial fire installer

Seven on-board circuits (two release, two pre-release, one manual release, one abort, and one Form C first-alarm relay) cover a complete suppression sequence from one module. Built-in field-configurable timers control abort and release delays, and four abort modes let you match the routine to the job's suppression design without custom programming. Every release, pre-release, manual, and abort circuit is individually supervised, so a wiring fault shows up as a specific trouble condition instead of a blind spot.

Key features

  • Complete releasing package in one module: two release circuits, two pre-release NACs, manual release input, abort input, and a Form C first-alarm relay
  • No separate releasing panel needed: communicates directly with the fire alarm panel's Signature loop controller
  • Field-configurable timers and four abort modes for a range of suppression sequences
  • Fully supervised circuits Ć¢ā‚¬ā€ faults on any release, pre-release, manual, or abort circuit report independently without disabling other circuits
  • Automatic device mapping Ć¢ā‚¬ā€ the module reports its own address and position on the loop, no manual loop mapping

System compatibility

Compatible with Kidde VS and VM Series control systems. UL, ULC, and FM listed; uses six module addresses on the Signature loop. Compatible releasing solenoids must be UL/ULC-listed and FM-approved.

Brand:
Kidde Commercial
Form factor:
Intelligent addressable releasing module, Signature loop
Compatible panels:
Kidde VS and VM Series control systems
Power riser input:
24 VDC power-limited; 25 mA max. supervisory, 170 mA to 4 A alarm
Release circuits:
2 supervised Class B, 2 A @ 24 VDC each, 4 valves max. per circuit
Pre-release circuits:
2 supervised Class B (steady visual + pulsed audible), 2 A @ 24 VDC each
Manual release / abort circuits:
Class B N.O. latching (manual release), Class B N.O. non-latching (abort)
First alarm output relay:
Form C, 3 A @ 24 VDC (0.6 power factor)
Signature data line:
5.2 to 19.95 VDC operating, 1000 µA supervisory/alarm current
Wiring:
18 to 12 AWG (2.5 to 0.75 mm²) terminals
Operating / storage temp:
32° to 120°F (0° to 49°C) operating; -4° to 140°F (-20° to 60°C) storage
Humidity:
0 to 93% noncondensing
Addressing:
Uses six module addresses on the Signature loop
Agency listings:
UL, ULC, FM
Does the GSA-REL need a separate releasing panel?
No. It communicates directly with the fire alarm control panel's Signature loop controller, so no separate releasing panel is required.
What suppression systems does it control?
Sprinkler, pre-action, and deluge systems, and it can release extinguishing agents such as CO2, Halon, or foam through its two supervised release circuits.
How many module addresses does it use on the loop?
Six module addresses.
Are the release and pre-release circuits supervised?
Yes. All release, pre-release, manual release, and abort circuits are individually supervised, and a fault on one circuit does not disable the others.
What panels is this compatible with?
Kidde VS and VM Series control systems.

Spec Sheet