The RBPS6A is a replacement main board for Kidde's 6.5-amp Booster Power Supply (EBPS6A/BPS6AC family) — a UL 864 10th-edition-listed, filtered and regulated 24 VDC supply used to add notification appliance circuits or auxiliary power where the base fire alarm panel's onboard NAC capacity runs out.
Built for the commercial fire installer
When a booster power supply's electronics fail in the field, the RBPS6A gets the cabinet back in service without replacing the whole enclosure, batteries, or wiring — the field wiring and steel cabinet stay put and only the main board changes. The 6.5A booster it services provides four Class B NACs (convertible to two Class A), each rated 3.0A with a 6.5A total budget, plus configurable auxiliary outputs and Genesis/Enhanced Integrity notification appliance synchronization.
Key features
- Direct field replacement for the main board in a 6.5-amp Kidde Booster Power Supply cabinet
- Four Class B NACs (convertible to two Class A), 3.0A max. per circuit, 6.5A total
- Configurable auxiliary outputs — any of the four NACs can be reassigned as an auxiliary output
- On-board diagnostic LEDs identify wiring or internal faults without a meter
- Supports Genesis and Enhanced Integrity notification appliance synchronization
System compatibility
Replacement electronics for the 6.5-amp Kidde Booster Power Supply family (EBPS6A, BPS6AC, BPS6A/230). UL, ULC, CSFM, NYC Fire Dept., and FM listed.
Specifications
| SKU | KD-RBPS6A |
|---|---|
| Brand | Kidde Commercial |
| Form factor | Replacement main circuit board for 6.5-amp Booster Power Supply cabinet |
| Compatible units | EBPS6A, BPS6AC, BPS6A/230 (6.5-amp Kidde Booster Power Supply family) |
| AC line voltage | 120 VAC or 220-240 VAC, 50/60 Hz, 390 watts |
| NAC ratings | 3.0A max. per circuit, 6.5A max. total, 18.2 to 27.0 VDC, Class A or Class B |
| Auxiliary output | Four configurable outputs replace any NAC (19.1 to 27.0 VDC); 200 mA dedicated aux (19.5 to 27.0 VDC) |
| Trouble relay | 2 A @ 30 VDC |
| Internal supervisory / alarm current | 70 mA (+35 mA per circuit set to AUX) standby; 270 mA alarm |
| Battery capacity | 10 Ah in cabinet (2x 12V10A); up to 65 Ah with external battery cabinet |
| Wire gauge | 18 to 12 AWG terminals |
| Operating temp / humidity | 32° to 120°F (0° to 49°C), 0 to 93% noncondensing |
| Output signal rates | Continuous, 3-3-3 temporal, or follow installed panel's NAC |
| Agency listings | UL, ULC, CSFM, NYC Fire Dept., FM |