You save

Kidde | Addressable SLC Contact Relay Module with Form C Output, UIO Mount | GSA-MCR

No reviews yet Write a Review
SKU:
KD-GSA-MCR

The GSA-MCR drops a supervised Form C dry relay contact onto the SLC loop without pulling a separate power supply. SLC-powered and UIO-mountable, it fits into standard 4-inch electrical boxes and programs from the panel - one address, one module, one less thing to troubleshoot on a callback.

Built for the commercial fire installer

Addressable on the SLC loop with support for both 64-point and 1000-point addressing. The relay output handles pilot-duty loads up to 30 VDC at 2A or 125 VAC at 0.5A (60W/62.5 VA max), covering elevator recall, door holder release, HVAC shutdown, and similar auxiliary control functions. Configurable for polarity reversal when the application requires it.

Key features

  • SLC-powered: no external power supply needed - draws from the signaling line circuit
  • Form C dry contact relay: configurable for normally open, normally closed, or polarity reversal
  • UIO mount: fits standard 4-inch square electrical boxes (1-1/2" and 2-1/2" deep)
  • Flexible wiring: accepts 12, 14, 16, or 18 AWG field wire
  • UL and ULC listed for commercial fire alarm applications

System requirements

Requires a compatible Kidde intelligent fire alarm control panel with SLC loop capacity. Each module occupies one SLC address. Mount in a standard North American 4-inch square electrical box.

Brand:
Kidde Commercial
Form factor:
UIO mount module
Communication:
SLC (Signaling Line Circuit) addressable
Power input:
SLC-powered (no external power required)
Relay type:
Form C dry contact, programmable
Contact ratings:
30 VDC 2A / 125 VAC 0.5A / 60W or 62.5 VA max (pilot duty)
Ground fault impedance:
10 kΩ
Operating temp:
32 to 120°F (0 to 49°C)
Operating humidity:
0 to 93% RH, noncondensing at 90°F (32°C)
Storage temp:
-4 to 140°F (-20 to 60°C)
Wire size:
12, 14, 16, or 18 AWG
Module address range:
01-64 (64-point) / 01-127 (1000-point)
Mounting:
Standard 4" square electrical box (1-1/2" or 2-1/2" deep)
Compliance:
UL, ULC listed
What panels does the GSA-MCR work with?
Compatible with Kidde intelligent fire alarm control panels that support SLC addressable modules. Check panel documentation for specific module capacity and addressing limits.
Does the GSA-MCR need a separate power supply?
No. The module draws power directly from the SLC loop. No external power supply or additional wiring required.
What type of relay contact does the GSA-MCR provide?
A single Form C dry relay contact rated for pilot duty: 30 VDC at 2A, 125 VAC at 0.5A, with a maximum resistive load of 60W or 62.5 VA. Configurable for polarity reversal.
What electrical boxes fit the GSA-MCR?
Standard North American 4-inch square electrical boxes: 2-1/2" deep (1-gang or 2-gang) or standard 1-1/2" deep box. UIO mounting style.
What wire sizes does the GSA-MCR accept?
12, 14, 16, or 18 AWG field wiring.

Spec Sheet