You save

Kidde | Electromagnetic Fire Door Holder, Flush Wall Mount, 25 Lbf, 24-120V AC/DC, UL/ULC Listed | 1504-AQN5

No reviews yet Write a Review
SKU:
KD-1504-AQN5

The Kidde 1504-AQN5 is a flush wall-mounted electromagnetic door holder built for fire-rated door assemblies. Multi-voltage operation (24 VAC/DC and 120 VAC) means it powers off whatever's already available at the door - no dedicated transformer needed on most jobs.

Built for the commercial installer

Mounts on a standard single-gang (2 x 4 inch) outlet box for fast, clean installation. UL and ULC listed under R6291. Fail-safe design releases the door automatically on power failure or fire alarm activation, keeping the building code-compliant without additional relay logic.

Key features

  • Flush wall mount on standard single-gang outlet box - no special hardware
  • Multi-voltage: 24 VAC, 24 VDC, or 120 VAC operation at just 0.015A draw
  • 25 Lbf (111N) holding force with adjustable swivel contact and shock-absorbing nylon ball
  • Fail-safe release on power loss or fire alarm signal
  • Durable aluminum housing with baked polyester powder paint finish
  • Long catch plate for flexible door-to-wall clearance positioning

System requirements

Connects to any fire alarm control panel (FACP) with a NAC or relay output configured for door holder release. Pairs with Kidde replacement armature CS2598-5 (long catch plate).

Brand:
Kidde Commercial
Form factor:
Flush wall mount electromagnetic door holder
Power input:
24 VAC 60 Hz / 24 VDC / 120 VAC 60 Hz
Power consumption:
0.015 Amps
Holding force:
25 Lbf (111N) nominal
Mounting:
Standard single-gang (2 x 4 inch) outlet box, flush wall mount
Catch plate:
Long (replacement armature: CS2598-5)
Housing:
Aluminum color, baked polyester powder paint
Contact type:
Adjustable swivel with shock-absorbing nylon ball
Compliance:
UL Listed, ULC Listed (R6291)
Does this door holder release on power failure?
Yes. The 1504-AQN5 is fail-safe - the electromagnet releases the door automatically when power is removed, whether from a fire alarm signal, manual pull station activation, or power outage.
What outlet box does this mount on?
Standard single-gang (2 x 4 inch) outlet box. The flush mount design sits inside the wall for a clean, low-profile installation.
Can I use this with 24V and 120V systems?
Yes. The 1504-AQN5 is multi-voltage: 24 VAC 60 Hz, 24 VDC, or 120 VAC 60 Hz. No separate transformer required when matching existing site voltage.
What is the replacement catch plate part number?
The replacement armature (long catch plate) is Kidde part CS2598-5, designed specifically for the 1504 series.
Is this UL listed for fire door holding?
Yes. UL and ULC listed under file number R6291 for electromagnetic door holding applications.

Spec Sheet