Kidde | Electromagnetic Fire Door Holder, Semi-Flush Wall Mount, Multi-Voltage 24-120V, UL/ULC Listed | 1505-AQN5

No reviews yet Write a Review
SKU:
KD-1505-AQN5

The Kidde 1505-AQN5 electromagnetic door holder keeps fire doors open during normal traffic and releases them automatically on alarm or power loss. Flush-mounted on a standard single gang box, it runs on 24 VAC, 24 VDC, or 120 VAC - no dedicated transformer needed if you're already pulling one of those voltages to the location.

Built for the commercial installer

Self-contained with no moving parts, the 1505-AQN5 installs directly to a standard 2 x 4 inch single gang outlet box. The shock-absorbing nylon swivel ball on the contact plate adjusts to meet the door at any angle, reducing callbacks from misalignment. Fail-safe operation means the door releases on power loss or fire alarm signal, maintaining NFPA 80 compliance without additional control hardware.

Key features

  • Multi-voltage operation: 24 VAC, 24 VDC, or 120 VAC at just 0.015 A - runs off existing panel or building power
  • Flush wall mount on standard single gang (2 x 4 inch) outlet box for a clean, low-profile installation
  • 25 lb holding force with adjustable swivel ball contact plate for reliable door engagement
  • Fail-safe release on power loss or alarm signal, NFPA 80 compliant
  • No moving parts, maintenance-free - no callbacks for mechanical wear
  • UL and ULC listed for fire door holding service
Brand:
Kidde Commercial
Form factor:
Semi-flush wall mount, short catch plate
Power input:
24 VAC 60 Hz, 24 VDC, or 120 VAC 60 Hz
Current draw:
0.015 A
Holding force:
25 lbf (111 N) nominal
Mounting:
Standard single gang (2 x 4 inch) outlet box
Operation:
Fail-safe (releases on power loss or alarm)
Contact plate:
Shock absorbing nylon swivel ball, adjustable
Finish:
Aluminum color, baked polyester powder paint
Shipping weight:
2.0 lb (0.91 kg)
Compliance:
UL Listed, ULC Listed, NFPA 80
Does this door holder release on power failure?
Yes. The 1505-AQN5 is fail-safe - it releases the door on any power interruption or fire alarm signal, maintaining NFPA 80 compliance.
What voltage does this door holder need?
Multi-voltage: 24 VAC (60 Hz), 24 VDC, or 120 VAC (60 Hz). Current draw is 0.015 A at any voltage. Runs off existing panel or building power without a dedicated transformer.
What size outlet box does it mount to?
Standard single gang (2 x 4 inch) outlet box. Flush wall mount with a low-profile semi-flush design.
How much holding force does this door holder have?
25 lbf (111 N) nominal. The adjustable swivel ball contact plate accommodates door angle variations for reliable engagement.
Is this door holder UL listed?
Yes. UL and ULC listed for fire door holding service.