Kidde | Conventional Double-Action Manual Fire Alarm Pull Station, Red, LIFT & PULL, UL/ULC Listed | MPSR-LP

No reviews yet Write a Review
SKU:
KD-MPSR-LP

The Kidde MPSR-LP is a conventional double-action manual fire alarm pull station built for commercial fire alarm systems. The two-step "Lift, then Pull" activation prevents accidental alarms from bumps and brushes while keeping operation fast and intuitive during a real emergency. Red Lexan housing with bold FIRE ALARM lettering meets visibility requirements and is instantly recognizable to building occupants and first responders.

Built for the commercial fire installer

Non-coded, single-circuit design with SPST contacts works with any conventional fire alarm control panel. Terminal block connections keep field wiring clean and fast. UL 38 and ULC listed for code-compliant installations in the US and Canada. ADA compliant per ANSI A117.1 for accessible mounting heights and activation force requirements.

Key features

  • Double-action activation: lift the protective cover, then pull the handle - reduces false alarms while meeting code for emergency operation
  • Heavy-duty red Lexan housing with FIRE ALARM lettering meets NFPA 72 visibility requirements
  • Universal conventional compatibility: SPST contacts work with any conventional 12V or 24V DC fire alarm panel
  • Terminal block connections for fast, clean field wiring - no soldering or crimping required
  • ADA compliant per ANSI A117.1 for accessible installations in commercial, educational, and healthcare facilities
  • UL 38 and ULC listed for approved use across the US and Canada

Mounting

Mounts to a standard single-gang electrical box. Compatible with both surface mount and semi-flush installations for flexible placement on any wall surface.

Brand:
Kidde
Form factor:
Double-action manual fire alarm pull station
Activation type:
Lift cover, then pull handle (two-step)
Circuit type:
Non-coded, single circuit
Contact type:
SPST
Housing material:
Red Lexan
Mounting:
Standard single-gang electrical box, surface or semi-flush
Compliance:
UL 38 listed, ULC listed
Accessibility:
ADA compliant per ANSI A117.1
Does this pull station work with any conventional fire alarm panel?
Yes. The MPSR-LP is a non-coded, single-circuit pull station with SPST contacts. It connects to any conventional fire alarm control panel operating on standard 12V or 24V DC fire alarm circuits via terminal block connections.
Does this work with any conventional fire alarm panel?
Yes. Non-coded, single-circuit with SPST contacts. Works with any conventional FACP on standard 12V or 24V DC fire alarm circuits. Terminal block connections for straightforward wiring.
What does double-action mean on a pull station?
Two steps to activate: lift the cover, then pull the handle. Reduces false alarms from accidental bumps while staying fast and intuitive during a real emergency.
Is this pull station ADA compliant?
Yes. Meets ADA requirements per ANSI A117.1 for mounting height and activation force. Suitable for commercial, educational, healthcare, and government facilities.
Is this UL listed for fire alarm use?
Yes. UL 38 and ULC listed for fire alarm station applications. Approved for code-compliant installations in the US and Canada.
How does this mount to the wall?
Mounts to a standard single-gang electrical box. Compatible with surface mount and semi-flush installations for flexibility on finished or unfinished wall surfaces.