You save

Kidde | 700 Series 6-Inch Universal Smoke Detector Base, 6 Terminals, Two-Wire and Four-Wire Head Compatible | 702U

No reviews yet Write a Review
SKU:
KD-702U

The Kidde 702U is a 6-inch universal detector base with 6 terminals, built for the 700 Series conventional photoelectric smoke detector line. It supports both two-wire (711U) and four-wire (741U) detector heads on a single base SKU, cutting down on inventory and simplifying commercial fire alarm installs.

Built for the commercial installer

The 702U drops into standard electrical boxes and accepts 12-18 AWG field wiring. A built-in continuity switch between terminals 1 and 2 lets you verify the alarm initiating circuit at rough-in before the detector head is installed - no extra test equipment needed. The switch opens automatically when the head snaps in. UL 268, FM, CSFM, and MEA approved for code-compliant commercial and industrial installations.

Key features

  • Universal compatibility: supports 711U (two-wire) and 741U (four-wire) detector heads on a single 6-terminal base
  • Continuity switch built in: verify circuit integrity at rough-in without the detector head installed
  • Non-polarity sensitive: 8.5-33VDC operating range works with virtually any conventional FACP
  • Low-profile 6-inch design blends into commercial ceiling tiles
  • 12-18 AWG field wiring for standard commercial fire alarm runs

Compatibility

The 702U base pairs with Kidde 711U and 741U conventional photoelectric smoke detector heads. For applications requiring auxiliary relay functionality, see the 702RU base. The 701U 3-terminal base is available for basic 711U two-wire installations.

Brand:
Kidde
Form factor:
6-inch round detector base, 6 terminals
Power input:
8.5-33VDC, non-polarity sensitive
Field wiring size:
12-18 AWG
Operating temp:
32°F to 120°F (0°C to 49°C)
Operating humidity:
0 to 95% RH, non-condensing
Base dimensions:
6" D x 0.06" H (15.24 cm x 1.3 cm)
Color:
White
Compatible heads:
711U (two-wire photoelectric), 741U (four-wire photoelectric)
Compliance:
UL 268, FM, CSFM, MEA approved
What detector heads work with the 702U base?
Compatible with the Kidde 711U (two-wire photoelectric) and 741U (four-wire photoelectric) smoke detector heads. For auxiliary relay outputs, use the 702RU base instead.
What is the difference between the 701U and 702U bases?
The 701U is a 3-terminal base for basic two-wire (711U) installs. The 702U has 6 terminals and supports both 711U and 741U heads - one base SKU for multiple head types.
Does the 702U have a continuity switch?
Yes. A switch between terminals 1 and 2 provides circuit continuity during rough-in so you can test the loop without a detector head. Opens automatically when the head snaps in.
What wire gauge does the 702U accept?
12-18 AWG field wiring.
Is the 702U listed for commercial fire alarm use?
Yes. UL 268, FM, CSFM, and MEA approved for commercial and industrial installations.

Spec Sheet