Kidde | SuperDuct Replacement Return Air Exhaust Tube for Duct Smoke Detectors | DDOS-RET

No reviews yet Write a Review
SKU:
KD-DDOS-RET

Replacement return air exhaust tube for the Kidde SuperDuct series of duct smoke detectors. This tube routes sampled air from the detector's sensing chamber back into the HVAC duct, completing the airflow circuit that makes duct smoke detection work. Keep spares on hand so a cracked or missing tube doesn't leave a detector offline.

Built for the commercial installer

The DDOS-RET is a direct drop-in for the exhaust tube included with SuperDuct SD-4W (four-wire) and SD-2W (two-wire) duct smoke detectors. It installs from the air duct side of the detector housing with a snap-fit connection - no special tools, no need to open or remove the detector cover.

Key features

  • Direct replacement: drop-in fit for all SuperDuct SD-4W and SD-2W duct smoke detector assemblies
  • Snap-fit installation: seats directly into the detector's exhaust tube socket from the duct side
  • No tools required: swap out a damaged tube in under a minute without pulling the detector
  • Completes the airflow circuit: returns sampled air from the sensing chamber back into the HVAC duct

System requirements

Requires a Kidde SuperDuct duct smoke detector (SD-4W or SD-2W series). The return air tube installs into the exhaust port on the detector housing. Air sampling tubes (SD-T series) are ordered separately based on duct width.

Brand:
Kidde Commercial
Form factor:
Replacement return air exhaust tube
Compatibility:
Kidde SuperDuct SD-4W (four-wire) and SD-2W (two-wire) duct smoke detectors
Installation:
Snap-fit, tool-free, installs from duct side
What SuperDuct models does the DDOS-RET fit?
The DDOS-RET is a direct drop-in replacement for the exhaust tube on all Kidde SuperDuct SD-4W (four-wire) and SD-2W (two-wire) duct smoke detectors.
What does the return air tube do?
Routes sampled air from the detector's sensing chamber back into the HVAC duct. Pressure differential between the sampling tube inlet and exhaust outlet pulls air through the sensing chamber while the system runs.
Do I need tools to replace the DDOS-RET?
No. The tube installs from the air duct side of the detector housing with a snap-fit connection. No need to open or remove the detector cover. Swap takes under a minute.
Is this the same as the sampling tube?
No. The sampling tube (SD-T series, ordered separately) draws air from across the duct width into the detector. The return air exhaust tube (DDOS-RET) sends it back. Both are required for the detector to function.

Spec Sheet