The Kidde SD-T18 is an 18-inch rigid metal air sampling tube for SuperDuct duct smoke detectors. It extends into the HVAC duct cross-section to draw air into the detector's sensing chamber, catching smoke conditions before they spread through the building's ventilation system.

Built for the commercial installer

Standard SuperDuct sampling tube spacing makes this a direct drop-in for new installs and replacements. The tube inserts from either the duct side or from inside the sensor compartment without opening the detector housing. It rotates in 45-degree increments so the air inlet holes align properly with duct airflow regardless of mounting orientation.

Key features

  • 18-inch reach: sized for standard commercial HVAC duct widths
  • Rigid metal construction: holds up to the vibration and temperature swings inside active ductwork
  • 45-degree rotational alignment: orient air inlet holes to face the airstream in any mounting position
  • Universal SuperDuct compatibility: works with both two-wire (SD-2W) and four-wire (SD-4W) SuperDuct duct smoke detectors
  • Front or rear installation: insert from the duct side or from inside the sensor compartment, whichever is more accessible on the job

System requirements

Requires a Kidde SuperDuct duct smoke detector (SD-2W or SD-4W series). The sampling tube connects to the detector assembly's sampling tube socket. An exhaust tube (included with the detector, not with this accessory) returns sampled air to the duct. Minimum duct air velocity of 100 ft/min required for proper airflow through the sampling tube.

Brand:
Kidde Commercial
Form factor:
18-inch rigid metal air sampling tube
Compatibility:
Kidde SuperDuct SD-2W (two-wire) and SD-4W (four-wire) duct smoke detectors
Mounting:
Inserts from duct side or sensor compartment; rotates in 45-degree increments for airflow alignment
Air velocity rating:
100 to 4,000 ft/min (per parent detector specification)
Shipping weight:
1.5 lb (0.7 kg)
What duct smoke detectors does the SD-T18 work with?
The SD-T18 is compatible with Kidde SuperDuct two-wire (SD-2W) and four-wire (SD-4W / SD-4WJ) duct smoke detectors.
Is the sampling tube included with the SuperDuct detector?
No. The sampling tube is ordered separately. The exhaust tube is included with the detector assembly.
How do I align the sampling tube with duct airflow?
The tube rotates in 45-degree increments inside the detector housing. Orient the air inlet holes to face the airstream for proper smoke sampling.
What other sampling tube lengths are available?
Kidde offers SuperDuct sampling tubes in 8", 18", 24", 36", 42", 60", 78", and 120" lengths. Choose based on your duct cross-section width.
What is the minimum duct air velocity for this tube?
The parent SuperDuct detector requires a minimum duct air velocity of 100 ft/min for air to flow through the sampling tube and reach the sensing chamber.