The FX-1000-2 is the 230 volt version of the FX-1000 intelligent fire alarm control panel. It ships with one 250-point loop installed and expands to four loops and 1,000 device addresses, with four notification appliance circuits, in a red surface-mount enclosure.
Built for the commercial fire installer
Buying capacity you do not need yet is wasted money; discovering you have none left mid-project is worse. This panel resolves that by expanding in 250-point increments through additional loop controller modules, so the head-end grows with the building instead of being replaced by it.
Each loop takes up to 125 detectors and 125 modules, addressed with rotary switches and mapped automatically by the panel. Loops wire Class A or Class B in Styles 4, 6, or 7 with up to 124 T-taps per loop. Four NACs deliver 6.0 A total, wired Class A or Class B.
Note that this variant runs on 230 VAC. For 110 VAC installations, order the FX-1000 instead.
Key features
- Expandable to 1,000 addresses: one 250-point loop installed, growing to four loops in 250-point increments
- 125 detectors and 125 modules per loop, addresses 1 to 125 for detectors and 126 to 250 for modules
- Four NACs wired Class B (Style Y) or two Class A (Style Z), 6.0 A FWR total
- Rotary addressing with automatic device mapping
- Up to 124 T-taps per loop
- 32 input zones and up to 8 remote annunciator drops over RS-485
- 230 VAC primary power for international and 230 V installations
- Optional Ethernet (SA-ETH) for central monitoring, programming and diagnostics
System requirements
Requires 230 VAC at 0.97 A max. Two 18 Ah batteries fit inside the FX-1000 cabinet; larger batteries need an external Kidde battery cabinet. The dialer is ordered separately. Order the SA-TRIM2 for a flush-mount installation. See compatibility list 3102355-EN for supported devices.
Specifications
| SKU | KD-FX-1000-2 |
|---|---|
| Brand | Kidde Commercial |
| Form factor | Red surface mount enclosure, intelligent fire alarm control panel |
| Device loops | 1 loop installed, expandable to 4, Class A or B (Styles 4, 6, 7), 250 addresses per loop |
| Point capacity | 1,000 device addresses max; 125 detectors and 125 modules per loop |
| Maximum T-taps per loop | 124 |
| Notification appliance circuits | 4 Class B (Style Y) or 2 Class A (Style Z) |
| NAC power | 6.0 A FWR total at 120/230 VAC 60 Hz; 5.0 A at 230 VAC 50 Hz; 2.5 A max per circuit |
| Power input | 230 VAC, 50-60 Hz, 0.97 A max |
| Panel current | Standby 172 mA, alarm 267 mA |
| Input zones | 32 max |
| Remote annunciator | 8 drops max, RS-485 Class A or B, 4,000 ft data line |
| Auxiliary power | Aux 1: 500 mA 24 VDC; Aux 2: 500 mA 24 VDC |
| Battery capacity | Up to two 18 Ah batteries in cabinet; external cabinet for larger |
| Operating voltage | 24 VDC panel |
| Ground fault impedance | 0 to 5 kohm |
| Alarm contact | Form C normally open, 24 VDC @ 1 A resistive |
| Trouble contact | Form C, 24 VDC @ 1 A resistive |
| Supervisory contact | Form A normally open, 24 VDC @ 1 A resistive |
| Terminal wire gauge | 12 to 18 AWG (0.75 to 2.5 sq mm) |
| Battery type | Sealed lead acid, 24 VDC |
| Battery charging current | 2.47 A max, 26 Ah capacity |
| Standby operation | 24 hour or 60 hour |
| Operating temp | 32 to 120 F (0 to 49 C) |
| Operating humidity | 0 to 93% non-condensing |