Kidde | Intelligent Optica Duct Detector Replacement Optical Sensor Tube, Rotary Addressed | KIR-DDOS-ROT

No reviews yet Write a Review
SKU:
KD-KIR-DDOS-ROT

The KIR-DDOS-ROT is the field-replaceable optical sensor tube assembly for the Kidde KIR-DDOS Intelligent Optica Duct Smoke Detector (Rotary Addressed). When the sensing chamber in an existing KIR-DDOS needs service or replacement, this drop-in tube gets the detector back online without pulling the entire duct housing off the HVAC run.

Built for fast field service

The sensor tube uses Kidde's Optica photoelectric (light-scattering) detection technology - the same sensing principle as the parent detector. It installs from either the duct side or inside the sensor compartment, and the sampling tube rotates in 45-degree increments so you can align it with duct airflow without repositioning the housing. No special tools required beyond what's already on the truck.

Key details

  • Direct replacement for KIR-DDOS: purpose-built for the Intelligent Optica Duct Smoke Detector (Rotary Addressed model only)
  • Dual-access installation: insert from the duct side or from inside the sensor compartment
  • Rotary sampling tube alignment: 45-degree increments for proper airflow orientation
  • Optica photoelectric sensing: light-scattering detection technology for reliable smoke detection in HVAC ducts
  • Minimizes downtime: swap the sensor tube in the field without removing or replacing the full duct detector assembly

System compatibility

The parent KIR-DDOS detector operates on Kidde Intelligent SLC loops and is compatible with the VS4, FX-350, and FX-64 series fire alarm control panels. This replacement sensor tube restores full detection capability to an existing KIR-DDOS installation.

Brand:
Kidde Commercial
Form factor:
Replacement optical sensor tube assembly
Detection method:
Photoelectric (light scattering) - Optica technology
Sampling tube rotation:
45-degree increments
Installation access:
Duct side or sensor compartment side
Compatible detector:
Kidde KIR-DDOS Intelligent Optica Duct Smoke Detector (Rotary Addressed)
Compatible panels:
Kidde VS4, FX-350, FX-64 series (via parent KIR-DDOS detector on SLC loop)
Listing:
UL 268A, ULC-S524 (as component of KIR-DDOS assembly)
What detector does the KIR-DDOS-ROT sensor tube fit?
The KIR-DDOS-ROT is the replacement optical sensor tube for the Kidde KIR-DDOS Intelligent Optica Duct Smoke Detector (Rotary Addressed). It is specific to the rotary-addressed model.
Can I replace the sensor tube without removing the duct housing?
Yes. The sensor tube is field-replaceable and can be installed from either the duct side or from inside the sensor compartment. The full duct housing stays mounted to the HVAC duct.
How do I align the sampling tube with duct airflow?
The sampling tube rotates in 45-degree increments. Rotate it until the inlet and exhaust tubes are perpendicular to the airflow direction inside the duct.
What fire alarm panels work with the KIR-DDOS duct detector?
The KIR-DDOS connects to Kidde Intelligent SLC loops on the VS4, FX-350, and FX-64 series fire alarm control panels.
Is this compatible with the KIR-DDOS2 (DIP-switch addressed) model?
No. The KIR-DDOS-ROT is designed for the rotary-addressed KIR-DDOS only. Check the Kidde catalog for the correct replacement sensor tube for the DIP-switch addressed model.