You save

Kidde | 120V NAC Power Expansion Transformer for 10-Zone FACP, 7.0A Output | F-XTR120

No reviews yet Write a Review
SKU:
KD-F-XTR120

The Kidde F-XTR120 is a 120V NAC power expansion transformer that increases the notification appliance circuit output on a Kidde Commercial 10-zone fire alarm control panel to 7.0 amps. When the standard FACP power budget falls short of the NAC load on the job, this transformer closes the gap without adding a separate booster power supply to the closet.

Built for the fire alarm installer

The F-XTR120 connects directly to the FACP and supplies additional NAC drive current so the panel can push more notification appliances per zone. Standard transformer form factor with wire leads for straightforward wiring to the panel's power input. Bracket-mounted for clean installation inside the fire alarm enclosure or an adjacent backbox.

Key features

  • Boosts NAC output to 7.0 amps on Kidde Commercial 10-zone fire alarm control panels
  • 120VAC input connects to standard building power
  • Compact transformer form factor with bracket mount fits inside or adjacent to the FACP enclosure
  • Wire-lead termination for direct connection to the panel's power circuit
  • Purpose-built accessory that eliminates the need for a standalone NAC booster power supply on qualifying panels

Compatibility

Designed for use with Kidde Commercial 10-zone fire alarm control panels. Verify panel compatibility and NAC loading requirements before specifying.

Brand:
Kidde
Form factor:
Bracket-mount power transformer
Input voltage:
120VAC
NAC output:
7.0 amps
Compatibility:
Kidde Commercial 10-zone FACP
What does the F-XTR120 do?
Increases NAC power output on a Kidde Commercial 10-zone FACP to 7.0 amps, letting the panel drive more horns, strobes, or horn-strobes per circuit without a separate booster power supply.
Which panels is this compatible with?
The F-XTR120 is designed for Kidde Commercial 10-zone fire alarm control panels. Confirm your specific panel model's compatibility and NAC loading requirements before specifying.
Does this replace a NAC booster power supply?
On qualifying Kidde 10-zone panels, yes. It expands built-in NAC output to 7.0A, eliminating the need for a standalone booster. For loads exceeding 7.0A, a separate NAC booster (Kidde EBPS series) is still required.
How is the F-XTR120 wired?
Connects via wire leads to the FACP's power input circuit. Bracket-mounts inside or adjacent to the fire alarm enclosure. Follow the panel's installation manual for wiring instructions and terminal locations.