Kidde | Genesis LED EG4 Series Wall Mount Horn, White, No Marking, Room Side Wiring Plate Included | EG4AWN

No reviews yet Write a Review
SKU:
KD-EG4AWN

The Kidde Genesis LED EG4 horn drops onto existing NAC circuits at 12 or 24V DC without a separate power supply run. Field-selectable output and temporal Code 3 patterning per ANSI/NFPA 72 let you dial in exactly what the AHJ wants on-site, not back at the shop.

Built for the commercial installer

The EG4 Series is Kidde's current-generation Genesis wall mount platform. UL 464 and ULC-S525 listed, it covers both US and Canadian jurisdictions. Low current draw means more devices per NAC circuit before you hit the panel's limit. The included GP10 room side wiring plate handles surface mount applications where a flush 4-inch box isn't available.

Key features

  • Field-selectable dBA output: High and Low settings adjustable at the device, no special tools
  • Temporal Code 3 pattern per ANSI/NFPA 72 plus non-temporal and coded options
  • Low current draw maximizes NAC circuit device count on the existing panel
  • Two-wire connection to standard NAC circuits at 12 or 24V DC (FWR or filtered)
  • Mounts on standard 4" square box, single-gang box, or the included GP10 surface mount wiring plate
  • Genesis synchronization protocol for coordinated signaling across multiple appliances
  • White housing, no marking for applications that don't require "FIRE" lettering

System requirements

Connects to any fire alarm control panel's NAC circuit providing 12 or 24V DC (FWR or filtered DC). Compatible with Kidde Intelligent and FX Series fire alarm systems. For synchronized temporal signaling, use with Genesis sync-compatible NAC circuits or the MDL3 sync module.

Brand:
Kidde Commercial
Form factor:
Wall mount horn (audible only, no strobe)
Power input:
12V DC or 24V DC (FWR or filtered DC) via NAC circuit
Signal pattern:
Temporal Code 3 (ANSI/NFPA 72), non-temporal steady, coded
Sound output:
Field-selectable High and Low dBA settings
Communication:
Two-wire connection to NAC circuit
Synchronization:
Genesis sync protocol compatible
Operating temp:
32°F to 120°F (0°C to 49°C)
Operating humidity:
10% to 93% non-condensing
Mounting:
Standard 4" square box, single-gang box, or GP10 surface mount wiring plate (included)
Color:
White
Marking:
No marking
Compliance:
UL 464, ULC-S525
Included accessories:
GP10 room side wiring plate
Does this horn include a strobe?
No. The EG4AWN is an audible-only wall mount horn. For a horn-strobe combination, look at the EG4AF series models in the Genesis LED EG4 line.
What voltage does the Genesis EG4 horn require?
12V DC or 24V DC, full-wave rectified (FWR) or filtered DC. It powers directly from your fire alarm panel's NAC circuit.
Can I adjust the sound output in the field?
Yes. The EG4 horn has field-selectable High and Low dBA output settings, adjustable at the device without special tools.
What signal patterns are available?
Temporal Code 3 per ANSI/NFPA 72, non-temporal (steady), and coded patterns.
What does it mount on?
Standard North American 4" square electrical box, single-gang box, or the included GP10 room side wiring plate for surface mount applications.
Is this listed for use in Canada?
Yes. The Genesis LED EG4 Series carries both UL 464 (US) and ULC-S525 (Canada) listings.
Why choose the no-marking version?
The "N" (no marking) version omits the "FIRE" lettering on the housing. Use it in applications where the AHJ does not require visible appliance marking, or where the horn serves a non-fire notification role.

Spec Sheet