p The Genesis LED EG1AWF is a compact wall-mount horn that delivers reliable alarm notification in commercial fire alarm systems while drawing less current than conventional signals. Low current draw means more devices on a single NAC circuit, fewer power supplies, and less time sizing the loop. /p h2 Built for the commercial installer /h2 p The EG1 mounts directly to standard electrical boxes (1-gang, 2-gang, 4-inch octagon, or 4-inch square) or surface-mounts to the wall. Field-selectable settings let you configure high or low dB output and constant or T3 temporal tone without swapping hardware. White housing with red FIRE marking. ADA compliant, UL listed. /p h3 Key features /h3 ul li strong Low current draw: /strong as low as 13 mA (DC), allowing more devices on a single NAC circuit /li li strong Field-selectable output: /strong high (85 dBA) or low (80 dBA) reverberant, plus constant or T3 temporal tone /li li strong Compact profile: /strong 3 x 4-5/8 x 1-1/8 inches, mounts flush to any standard electrical box /li li strong Universal mounting: /strong fits 1-gang, 2-gang, 4-inch octagon, and 4-inch square boxes /li li strong Wide voltage range: /strong operates on 16-33 VDC or 16-33 VFWR for flexible power sourcing /li li strong ADA compliant /strong with UL 1971, UL 1638, and UL 464 listings /li /ul h3 System requirements /h3 p Connects to any fire alarm control panel (FACP) with standard NAC circuit output. Requires 16-33 VDC or 16-33 VFWR. Uses 12-18 AWG field wiring. /p
Brand:
Kidde
Form factor:
Compact wall-mount horn
Power input:
16-33 VDC or 16-33 VFWR
Current draw (high):
23 mA (DC) / 29 mA (VFWR)
Current draw (low):
13 mA (DC) / 15 mA (VFWR)
Sound output (high):
85 dBA reverberant / 92 dBA anechoic
Sound output (low):
80 dBA reverberant / 86 dBA anechoic
Tone pattern:
Constant or T3 temporal, field-selectable
dB selection:
High or low, field-selectable
Color:
White
Marking:
FIRE (red)
Wire size:
12-18 AWG
Compatible boxes:
1-gang, 2-gang, 4-inch octagon, 4-inch square
Dimensions:
3 x 4-5/8 x 1-1/8 in. (7.62 x 11.75 x 2.86 cm)
Operating temp:
32-122°F (0-50°C)
Operating humidity:
0-93% noncondensing
Environment:
Indoor use only
Compliance:
UL 1971, UL 1638, UL 464, FCC, ICC, CSFM, ADA
How many Genesis EG1 horns can I put on a single NAC circuit?
Low current draw (as low as 13 mA at 24 VDC on the low setting) allows significantly more notification devices per NAC than conventional horns. Calculate your total loop current against your FACP's NAC output capacity.
Can I select high or low dB output in the field?
Yes. The EG1AWF has a field-selectable switch for high (85 dBA reverberant) or low (80 dBA reverberant) output. No hardware swap needed.
What tone patterns does this horn support?
Constant and T3 temporal, field-selectable. T3 temporal is the standard fire evacuation pattern (three pulses, pause, repeat).
What electrical boxes does this mount to?
Standard 1-gang, 2-gang, 4-inch octagon, and 4-inch square boxes. Can also surface-mount directly to the wall.
Is this horn rated for outdoor use?
No. The EG1 series is rated for indoor use only. Operating range is 32-122°F (0-50°C), 0-93% noncondensing humidity.